Chapter 4 Settings and Test
29
e) t5: Fast-dropping, time is 0.2s maximum, mainly used to discharge.
f) If the test is judged as fail before stage t4, there is no Ramp Down stage.
U2 is test voltage. U1 is output starting voltage (U2*XX% ).
4.3.5 Display Brightness
Backlight Brightness of LCD screen, including 8 steps.
4.3.6 Theme
Settings of the background/foreground color. Three themes Light Blue, Deep Blue and Light
Gray.
4.3.7 Language
Chinese/English.
4.3.8 Communication
1) Address: 0~255.
2) Baud rate: 9600, 19200, 38400, 57600.
3) Protocol: Built-in Ainuohex protocol or SCPI protocol.
4.3.9 Display of Result
There are two types:
Hold at the result of the failed step or the first step after completing the
test
The test result of each step in the group is listed after completing the test
Figure 4-3-4 Display the result of single step after completing the test