EasyManua.ls Logo

AIRTRONICS SD-10G - 13.TRIM STEP (CONTROL SURFACE TRIM STEP RESOLUTION)

AIRTRONICS SD-10G
212 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 90
aero Flight Mode menu
TRIM setting range is -150% to 150%. The default setting is 0%.
1) Press the Navigation Pad
3456
to highlight the channel you would
like to change the Trim percentage value for, then press the YES/+ or
NO/- keys to change the Trim percentage value.
Press the YES/+ and NO/- keys at the same time to set the Trim
percentage value to 0% for the selected channel.

The Trim Step function allows you to adjust how far the servo travels when the trim switch is moved. This allows you to change the
Trim function resolution to suit your preference. For example, in the default conguration, when you move the elevator trim switch,
the Trim percentage value changes in 6% increments. You can increase the resolution by decreasing the Trim Step value, so that
the servo travels less when you move the trim switch. This makes it possible to ne-tune the trim settings extremely accurately. In
addition, you could decrease the resolution by increasing the Trim Step value, so that the servo travels more when you move the
trim switch. This makes setting large amounts of trim faster, but the trim setting may not be as accurate. You can choose to program
Trim Step values separately for each of the ve Flight Modes or you can use the same Trim Step programming values across all
ve Flight Modes.
Transmitter F-MODE
Programming F-MODE
Transmitter F-MODE refers to the Flight Mode that the transmitter is currently operating in. Programming F-MODE refers
to the Flight Mode that you would like to change the programming for.
Choosing the Flight Mode - Common or Separate
When set to COM (Common), the TRIM STEP settings will be the same regardless of which Flight Mode the transmitter is operating
in. You cannot program TRIM STEP settings separately for each Flight Mode. When set to SEP (Separate), you can program
different TRIM STEP settings separately for each Flight Mode.
3) Press the F-MODE key to choose the F-MODE number you would like to program the Trim Step function for. Choose from N,
1, 2, 3, or 4. The F-MODE (N) display will change, indicating which Flight Mode you are programming the Trim Step function for.
1) Press the Navigation Pad
56
to highlight TRIM STEP, then press the
ENTER key to display the TRIM STEP menu. The cursor will default to
COMMON>COM.
2) Press the YES/+ or NO/- keys to choose either COM or SEP. If set to
COM, skip to the Setting the Trim Step Values section. If set to SEP,
see step 3 below.
Changing the Trim Step Values
1) Press the Navigation Pad
3456
to highlight the channel you would
like to change the Trim Step value for, then press the YES/+ or NO/- keys
to change the Trim Step value.
TRIM STEP setting range is 1 to 30. The default setting is 6. Increasing
the Trim Step value causes the servo to travel more when the trim switch
is moved (lower resolution). Decreasing the Trim Step value causes the
servo to move less when the trim switch is moved (higher resolution).

Table of Contents