EasyManua.ls Logo

Alcatel-Lucent 7210 SAS-X - Page 157

Alcatel-Lucent 7210 SAS-X
948 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Virtual Leased Line Services
7210 SAS-X, R6 OS Services Guide Page 157
pseudowires. All commands and functions that are applicable to spoke-sdps in today’s
implementation are supported, except for those that explicitly depend on an LDP session on the
SDP or as stated below. Likewise, all existing functions on a given service SAP are supported if
the spoke-sdp that it is matched to is MPLS-TP.
The following describes how to configure MPLS-TP on an Epipe VLL. However, similar
configuration applies to other VLL types.
A spoke-sdp bound to an SDP with the mpls-tp keyword cannot be no shutdown unless the
ingress label, the egress label, the control word, and the pw-path-id are configured.
*7210SAS>config>service>epipe# info
----------------------------------------------
sap 1/1/10:1.111 create
exit
spoke-sdp 1:111 create
ingress
vc-label 2111
exit
egress
vc-label 2111
exit
control-word
pw-path-id
agi 0:111
saii-type2 4294967295:0.0.0.42:111
taii-type2 4294967295:0.0.0.43:111
exit
no shutdown
exit
no shutdown
----------------------------------------------
*7210SAS>config>service>epipe#
The pw-path-id context is used to configure the end-to-end identifiers for a MS-PW. These may
not coincide with those for the local node if the configuration is at an S-PE. The saii and taii are
consistent with the source and destination of a label mapping message for a signaled PW.
The control-channel-status command enables static PW status signaling. This is valid for any
spoke-sdp where signaling none is configured on the SDP (for example, where T-LDP signaling
is not in use). The refresh timer is specified in seconds, from 10-65535, with a default of 0 (off).
This value can only be changed if control-channel-status is shutdown. Commands that rely on
PW status signaling are allowed if control-channel-status is configured for a spoke-sdp bound to
an SDP with signaling off, but the system will use control channel status signaling rather than T-
LDP status signaling. The ability to configure control channel status signaling on a given spoke-
sdp is determined by the credit based algorithm described below. Control-channel-status for a
particular PW only counts against the credit based algorithm if it is in a no shutdown state and has
a non-zero refresh timer.
Note that a shutdown of a service will result in the static PW status bits for the corresponding PW
being set.

Table of Contents

Related product manuals