Service Entities
Page 50 7210 SAS-X, R6 OS Services Guide
no shutdown
exit
no shutdown
exit
All the Sub Ring nodes part of Sub Ring with non-virtual-link should be configured with “sub-ring
non-virtual-link” option.
eth-ring 1
sub-ring non-virtual-link
exit
path a 1/1/1 raps-tag 1.1
eth-cfm
mep 5 domain 1 association 4
ccm-enable
control-mep
no shutdown
exit
exit
no shutdown
exit
path b 1/1/2 raps-tag 1.1
eth-cfm
mep 6 domain 1 association 3
ccm-enable
control-mep
no shutdown
exit
exit
no shutdown
exit
no shutdown
exit
# Control Channel for Sub-Ring using non-virtual-link on interconnecting node:
vpls 1 customer 1 create
description "Ring 1 Control termination"
stp shutdown
sap 1/1/3:1.1 eth-ring 1 create //path a control
stp shutdown
exit
no shutdown
exit
# Configuration for the ring data into the VPLS Service
vpls 5 customer 1 create
description "VPLS Service at PE1"
stp
no shutdown
exit
sap 1/1/3:2.2 eth-ring 1 create
stp shutdown
exit
sap 1/1/5:1 create
exit
mesh-sdp 5001:5 create //sample LDP MPLS LSPs
exit
mesh-sdp 5005:5 create
exit