Publication 1762-UM001D-EN-P - March 2004
Specifications A-9
Bus Current
Draw (max.)
115 mA at 5V dc
(0.575W)
115 mA at 5V dc
(0.575W)
175 mA at 5V dc
(0.88W)
80 mA at 5V dc
(0.40W)
90 mA at 24V dc
(2.16W)
120 mA at 5V dc
(0.60W)
140 mA at 24V
dc (3.36W)
110 mA at 5V dc
(0.55W)
110 mA at 24V
dc (2.64W)
Heat
Dissipation
(max.)
2.9 Watts 1.61 Watts 2.9 Watts at 30
°C
(86°F)
2.1 Watts at 55
°C
(131°F)
2.9 Watts 5.6 Watts 2.8 Watts
Signal Delay
(max.) –
resistive load
On Delay: 1/2 cycle
Off Delay: 1/2 cycle
On Delay: 0.1 ms
Off Delay: 1.0ms
On Delay: 0.1 ms
Off Delay: 1.0 ms
On Delay: 10 ms
Off Delay: 10
ms
On Delay: 10 ms
Off Delay: 10
ms
On Delay: 10 ms
(max) 6 ms
(typical)
Off Delay: 20 ms
(max)
12 ms (typical)
Off-State
Leakage
(max.)
2 mA at 132V,
2.5 mA at 265V
1.0 mA 1.0 mA 0 mA 0 mA 0 mA
On-State
Current (min.)
10 mA 1.0 mA 1.0 mA 10 mA 10 mA 100 mA
On-State
Voltage Drop
(maximum)
1.5V at 0.5 A 1.0V dc 1.0V dc Not Applicable Not Applicable Not Applicable
Continuous
Current per
Point (max.)
0.25A at 55°C
(131°F)
0.5A at 30°C (86°F)
0.5A at 55°C (131°F)
1.0A at 30°C (86°F)
0.5A at 55°C (131°F)
1.0A at 30°C (86°F)
2.5A (Also see “Relay Contact
Ratings” on page A-5.)
7A (Also see
“Relay Contact
Ratings” on
page A-5.)
Continuous
Current per
Common
(max.)
1.0 A at 55°C (131°F)
2.0 A at 30°C (86°F)
4.0A at 55°C (131°F)
8.0A at 30°C (86°F)
4.0A at 55°C (131°F)
8.0A at 30°C (86°F)
8 A 8A 7A (Also see
“Relay Contact
Ratings” on
page A-5.)
Continuous
Current per
Module
(max.)
2.0 A at 55°C (131°F)
4.0 A at 30°C (86°F)
4.0 A at 55°C;
8.0 A at 30°C
4.0A at 55
°
C (131°F)
8.0A at 30
°
C (86°F)
16 A 16A 30A (Also see
Module Load
Ratings
1762-OX6I on
page A-11
Surge Current
(maximum)
5.0 A (Repeatability
is once every 2
seconds for a
duration of 25 msec.
2.0A (Repeatability
is once every 2
seconds at 55°C
(131°F), once every
second at 30°C
(86°F) for a duration
of 10 msec.)
2.0A (Repeatability
is once every 2
seconds at 55°C
(131°F), once every
second at 30°C
(86°F) for a duration
of 10 msec.)
See “Relay Contact Ratings” on
page A-5
See “Relay
Contact
Ratings” on
page A-5
Power Supply
Distance
Rating
6 (The module may not be more than 6 modules away from the power supply.)
Table A.14 Output Specifications
Spec. 1762-OA8 1762-OB8 1762-OB16 1762-OW8 1762-OW16 1762-OX6I