EasyManua.ls Logo

Amada HF-2500A - Page 131

Amada HF-2500A
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
990-371 E-9
P2LDLY1 {delay_value} Pulse 2 Lower Delay Start Time For
Lower Limit
P2LDLY2 {delay_value} Pulse 2 Lower Delay End Time For
Lower Limit
P2UDLY1 {delay_value} Pulse 2 Upper Delay Start Time For
Upper Limit
P2UDLY2 {delay_value} Pulse 2 Upper Delay End Time For
Upper Limit
limit_value
is the parameter that specifies the range of the valid readings. If the reading was
within the range of the limit_value, no alarm will occur. If the reading was out
of the valid
range, an alarm will occur. If the monitor type is KA, the limit_value is in unit of 1
A. If the
monitor type is V, the limit_value is in unit of 1 mV. If the monitor type is kW, the limit_
value
is in unit of 1 W. The valid number for limit_value is 1 through 9999 and 0 is for none.
The delay_value is the parameter that defines the time for the given period in 0.1
ms. Valid
range is from 0 to 99. Lower delay value is only valid during WELD time. Upper delay value
is valid during UP time, WELD time, and DOWN time.
Command
RELAY {READ | SET} <crlf>
[parameter_name value<crlf>]
<lf>
Control State
Any except while welding
Description
Provides control over the Power Supply
schedule parameters for relay settings. When used
with the "READ
" keyword, the relay settings of the currently loaded schedule are returned (see
RELAY under Power Supply Originated Commands). When the "SET
" keyword is used, the
host may set (change) the value of one or more of the relay settings of the currently loa
ded
schedule. The following is a list of valid literal substitutions for the parameter_name and
value
variables:
ACTIVE1 { HIGH | LOW } Relay 1 Active High or Active Low
CONDITION1 condition_value Relay 1 Active Conditions
SUBCOND1 extended_condition_value Relay 1 Extended Conditions.
ACTIVE2 { HIGH | LOW } Relay 2 Active High or Active Low
CONDITION2 condition_value Relay 2 Active Conditions
SUBCOND2 extended_condition_value Relay 2 Extended Conditions.
ACTIVE3 { HIGH | LOW } Relay 3 Active High or Active Low
CONDITION3 condition_value Relay 3 Active Conditions
SUBCOND3 extended_condition_value Relay 3 Extended Conditions.
ACTIVE4 { HIGH | LOW } Relay 4 Active High or Active Low
CONDITION4 condition_value Relay 4 Active Conditions
SUBCOND4 extended_condition_value Relay 4 Extended Conditions.
condition_value: { ALARM | LIMITS | WELD | END | P1HI | P1LOW | P2HI
| P2LOW | MG3 }
NOTE: extended_condition_value:
P1HI, P1LOW:
Pulse 1 hi/low limit reached.
P2HI, P2LOW: Pulse 2 hi/low limit reached.

Table of Contents

Related product manuals