APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
E-10 990-371
SYSTEM {READ | SET}<crlf>
[
parameter_name value<crlf>]
Provides control over the
Power Supplies system parameters. When used with the "READ
"
keyword, all system parameters are returned (see
SYSTEM under
Power Supply Originated
Commands
). When used with the "SET
" keyword, the host may set (change) the value of one
or more of the system parameters.
The following is a list of valid literal substitutions for the
parameter_name and value
{ light_value } LCD contrast
{ loudness_value } Buzzer Loudness
{ OFF | ON } end of cycle buzzer
{ PEAK | AVG } Display mode
{ switch_state } Input Switch Type
{ switch_state } Control Signals Type
{ AUTO | REMOTE | NONE } Firing Switch Type
{ OFF | ON } Update Graph
{ OFF | ON } Footswitch weld abort
{ NONE | 10 | 20 | 30 } Switch debounce time in
msec
These parameters pertain to the settings of the option menus available via the front panel user
interface.
light_value
is a number 0 to 100 for brightness of the LCD. 0 is dark and 100 is the
brightest.
loudness_value is a number 0 to 100 for buzzer loudness. 0 is off and 100 is the loudest.
switch
_state: { MECHOPEN | MECHCLOSED | OPTOOPEN | OPTOCLOSED