EasyManua.ls Logo

Amada HF-2500A - Page 132

Amada HF-2500A
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX E. COMMUNICATIONS
HF-2500A HIGH FREQUENCY WELD CONTROL
E-10 990-371
Command
SYSTEM {READ | SET}<crlf>
[
parameter_name value<crlf>]
<lf>
Control State
Any
Description
Provides control over the
Power Supplies system parameters. When used with the "READ
"
keyword, all system parameters are returned (see
SYSTEM under
Power Supply Originated
Commands
). When used with the "SET
" keyword, the host may set (change) the value of one
or more of the system parameters.
The following is a list of valid literal substitutions for the
parameter_name and value
variables:
LIGHT
{ light_value } LCD contrast
LOUDNESS
{ loudness_value } Buzzer Loudness
BUZZER
{ OFF | ON } end of cycle buzzer
DISPLAY
{ PEAK | AVG } Display mode
SWSTATE
{ switch_state } Input Switch Type
CTSTATE
{ switch_state } Control Signals Type
FIRESW
{ AUTO | REMOTE | NONE } Firing Switch Type
GRAPH
{ OFF | ON } Update Graph
WELDABORT
{ OFF | ON } Footswitch weld abort
DEBOUNCE
{ NONE | 10 | 20 | 30 } Switch debounce time in
msec
These parameters pertain to the settings of the option menus available via the front panel user
interface.
light_value
is a number 0 to 100 for brightness of the LCD. 0 is dark and 100 is the
brightest.
loudness_value is a number 0 to 100 for buzzer loudness. 0 is off and 100 is the loudest.
switch
_state: { MECHOPEN | MECHCLOSED | OPTOOPEN | OPTOCLOSED
| PLC0V | PLC24V}

Table of Contents