Cleaning, maintenance and repairs
152
Primera BAG0175.3
12.9.1 Checking the hydraulic fluid filter
WARNING
Beforehand, depressurise the hy-
draulic system.
The oil filter can only be checked during oil circu-
lation.
Green Filter fully functional
Red Replace filter
Hydraulic fluid filter (1) with contamination indi-
cator(2).
To remove the filter, twist off the filter cover and
remove the filter.
After replacing the filter, press the contamination
indicator back into place.
Fig.
130
On-board hydraulic system oil filter with contam-
ination level indicator.
12.10 Upper and lower link pins
WARNING
Risk of contusions, catching, and knocks when the machine
unexpectedly releases from the tractor.
Check the upper and lower link pins for visible damage each time you
couple the machine. Replace the upper and lower link pins in the
event of clearly visible wear.