Assembly and function
UF 01 DB 238. 07.04
43
4 Assembly and function
The following chapter informs you about the assembly of the field
sprayer and the functions of the individual components.
4.1 Tank level indicator
Tank volume [l] = indicated scale figure x 10
The tank level indicator (Fig. 12/1) indicates the
contents [l] in the spray cocktail tank. Read the
tank contents off the scale (Fig. 12/2) on the
reading edge (Fig. 12/3) of the pointer.
Fig. 12
4.2 Agitation
The engaged agitator mixes the spray cocktail in
the spray cocktail tank and in this way provides a
homogeneous spray cocktail. The agitation in-
tensity is set with the aid of the step tap (Fig.
13/1).
The agitation intensity is adjusted in 6 steps "0,
1, 2, 3, 4, 5". In position "0" agitation is switched
off. The highest intensity agitation is achieved in
position "5". For spraying operation select agita-
tion step "2".
Fig. 13
1
2