4.9.7.2.4 Manually enter impulses per litre – return flow meter
1. Recall via the functional field the en-
tering "Enter the impulses for flow meter 2".
2. Enter the calibration value "Impulses per
litre". Please refer to chapter "Entering of
text and figures", page 59.
3. Recall the functional field
.
Fig. 52
4.9.7.3 Nominal PTO shaft rev. speed
Hint!
x You can store for 3 tractors
x the nominal PTO shaft ref. speeds. Please refer to
chapter "Storage of the nominal PTO shaft rev. speeds
for different tractors", page 69.
x the impulses per PTO shaft rev. Please refer to chapter
"Storage of impulses per PTO shaft rev.", page 70.
x When selecting an already computer stored tractor the rele-
vant values for the PTO nominal rev. speed and the im-
pulses per 100m are simultaneously taken over.
x The
monitors the nominal PTO shaft rev.
speed. During spraying operation an alarm signal sounds
when the alarm limit is exceeded or falls short. Please refer
to chapter "Store alarm limit for PTO shaft rev. speed", page
71.
4.9.7.3.1 Enter the nominal PTO shaft rev. speed
1. Recall via the functional field the input
"Please enter nominal PTO shaft rev.
speed".
2. Enter the nominal PTO shaft rev. speed,
e.g. 540 R.P.M.
Enter for the nominal PTO shaft rev. speed
the value "0" when
• no PTO shaft rev. speed sensor exists.
• the rev. speed monitoring is not wanted.
Please refer to chapter "Entering of text and
figures", page 59.
3. Actuate the functional field
.
4. Enter the alarm limit for the rev. speed
monitoring. Please refer to chapter "Store
alarm limit for PTO shaft rev. speed", page
71.
Fig. 53