82
UF 01 DB 238. 07.04
4.9.8.2.3 Configuration of the tank filling level indicator
1. Via the functional field the equipment
"Filling level indicator" is switched on and
off.
→ In the display appears either the word "on"
(filling level indicator existing and switched
on) or "off" (no filling level indicator existing
or switched off).
2. Recall via the functional field
"Calibra-
tion filling level indicator", please refer to
chapter "Calibration filling level indicator",
page 83.
Fig. 77
4.9.8.2.4 Calibration filling level indicator
1. Fill an exactly defined quantity of water
(min. 500 litres) into the spray cocktail tank.
2. Recall via the functional field the input
"Please enter the actual filling level". Please
enter the accurate value for the quantity of
water filled into the spray cocktail tank.
Fig. 78
4.9.8.2.5 Enter nozzles per boom part section
Hint!
The numbering of the boom sec-
tions for the spray line is carried out
from outer left hand side to outer
right hand side. See Fig. 79.
Fig. 79
1 2 3
5 4