Assembly and function
48
UF 01 DB 238. 07.04
4.4.6 Urea filter
Special option
Order No.: 707 400
When filling in urea, the urea filter (Fig. 20/1)
prevents that undiluted fertiliser particles reach
the suction range and possibly block the suction
filter.
Fitting the urea filter:
1. Remove the plug of the screw-in opening in
the spray cocktail tank sump.
2. Screw the urea filter into the bottom.
Filter surface: 415 mm²
Mesh width: 0.32 mm
Fig. 20
4.5 Clean water tank
The clean water tank (Fig. 21/1) contains clear
water without chemical contact. This water is
used for
• diluting the residual amount in the spray
cocktail tank after having finished the spray-
ing operation.
• cleaning (flushing) the entire field sprayer in
the field.
• cleaning the suction device and the spray
lines with filled spray cocktail tank.
Fig. 21/...
(2) Screw lid with venting valve for the filling
opening.
Fig. 21