-X BAG0235.4 01.23
• The fertiliser spreader is coupled to the tractor and the hydraulic
hoses are connected.
• The settings have been configured.
1. Couple the universal joint shaft at a low tractor engine speed.
• Never open the two sliders until the required universal joint shaft
speed has been reached.
• Set the universal joint shaft speed to 540 rpm unless indicated
otherwise in the setting chart.
• While spreading, always observe the selected operational
speeds indicated on the setting chart.
• Maintain a constant spreading disc speed.
2. Open both levers of the two-way control.
3. Actuate tractor control unit (relieve load).
→ Open both sliders
and drive to the spreading area.
4. When you have finished spreading:
4.1 Actuate tractor control unit.
→ Close the slider.
4.2 Close both levers of the two-way control.
4.3 Uncouple the universal joint shaft at a low tractor engine
speed.
• After long transport with a full hopper, ensure that the yield is
correct before spreading begins.
•
If, despite an identical slider position, you determine that the two
hopper tips are not emptying uniformly, check the basic setting
of the sliders.
• The service life of the spreading vanes depends on the kinds of
fertiliser used, the operating times and the spread rates.