VNA Commands 5-2 :CALCulate Subsystem
S412E PM PN: 10580-00319 Rev. N 5-15
:CALCulate<Tr>:LIMit:UPPer:POINt:DELete
Description: Deletes the upper limit point of the given trace <Tr>. After deletion,
the point that is immediately to the left of the point that was deleted
becomes the active point. <Tr> is the trace number in the range 1 to 4.
If no trace number is specified, then the <Tr> parameter defaults to
trace number 1. Note that deletion is valid only if 2 or more limit points
are active.
Parameter: NA
Query Syntax: NA (no query)
Query Response: NA
Example: To delete trace 3 upper limit current active point:
:CALCulate3:LIMit:UPPer:POINt:DELete
Related Command: :CALCulate<Tr>:LIMit:UPPer:POINt:ADD
Front Panel Access: Shift 6 (Limit), Limit Edit, Delete Point
:CALCulate<Tr>:LIMit:UPPer:POINt:LEFT
Description: Sets the limit point to the left of the upper limit active point of the given
trace <Tr> as the new active point. <Tr> is the trace number in the
range 1 to 4. If no trace number is specified, then the <Tr> parameter
defaults to trace number 1.
Parameter: NA
Query Syntax: NA (no query)
Query Response: NA
Example: To make the upper limit point to the left of the current active point of
trace 2 as the new active point:
:CALCulate2:LIMit:UPPer:POINt:LEFT
:CALC2:LIM:UPP:POIN:LEFT
Related Command: :CALCulate<Tr>:LIMit:UPPer:POINt:RIGHt
Front Panel Access: Shift 6 (Limit), Limit Edit, Next Point Left