EasyManua.ls Logo

Anritsu LMR Master S412E - 17-8:MMEMory Subsystem

Anritsu LMR Master S412E
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TETRA Commands 17-8 :MMEMory Subsystem
S412E PM PN: 10580-00319 Rev. N 17-15
17-8 :MMEMory Subsystem
The Mass Memory subsystem contains functions that provide access to the instrument’s
setup and data storage.
:MMEMory:LOAD:STATe <integer>,<filename>
Description: Recalls a previously stored instrument setup in the current save
location.
The setup file to be loaded is specified by <filename>. <filename>
should be enclosed in either single quotes (' ') or double quotes (" ") and
should contain a file extension ".stp". Use the command MMEMory:MSIS
to set the current save location. The <integer> parameter is not
currently used, but it must be sent. Send a 1.
Cmd Parameters: <integer>,<filename>
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To recall a setup file:
:MMEMory:LOAD:STATe 1,"xxx.stp"
Front Panel Access: Shift 7 (File), Recall
:MMEMory:LOAD:TRACe <integer>,<filename>
Description: The instrument must be in the mode of the saved trace in order to recall
that trace. Use :INSTrument:SELect or :INSTrument:NSELect to
set the mode.
Recalls a previously stored measurement trace from the current save
location. The saved measurement trace to be loaded is specified by
<filename>. <filename> should be enclosed in either single quotes
(' ') or double quotes (" ") and should contain a file extension. Note that
the trace specified by <filename> should be available at the current
save location. Use the command MMEMory:MSIS to set the current save
location. The <integer> parameter is not currently used, but it must
be sent. Send a 1.
After recalling the data file, the unit is put into HOLD mode. Setting
the unit back to RUN mode will clear the recalled data, but keep the
recalled setup.

Table of Contents