Fixed WiMAX Commands 7-3 :DISPlay Subsystem
S412E PM PN: 10580-00319 Rev. N 7-5
7-3 :DISPlay Subsystem
This subsystem provides commands that modify the display of data for the user. They do not
modify the way in which data are returned to the controller.
:DISPlay:WINDow:TRACe:MAXHold OFF|ON|0|1
:DISPlay:WINDow:TRACe:MAXHold?
Title: Max Hold State
Description: Specifies whether the Max Hold is ON or OFF. The default value is 0.
That is, sending :DISP:WIND:TRAC:MAXH is equivalent to sending
:DISP:WIND:TRAC:MAXH ON. The query version of the command
returns a 1 if Max Hold is set to ON and returns a 0 if the Max Hold is
set to OFF. Note that this command is available only in the Spectrum
and EVM vs. Sub-carrier views.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: 0
Related Command: :CONFigure:RF SPECtrum
:CONFigure:DEMod EVSCarrier
Front Panel Access: Shift-5 (Trace), Max Hold
:DISPlay:WINDow:TRACe:Y[:SCALe]:OFFSet <rel ampl>
:DISPlay:WINDow:TRACe:Y[:SCALe]:OFFSet?
Title: Power Offset
Description: Sets the power offset value for the y-axis.
Parameter: <rel ampl>
Default Value: 0 dB
Default Unit: dB
Range: 0 dB to 100 dB
Front Panel Access: Amplitude, Power Offset