7-3 :DISPlay Subsystem Fixed WiMAX Commands
7-6 PN: 10580-00319 Rev. N S412E PM
:DISPlay:WINDow:TRACe:Y[:SCALe]:PDIVision <value>
:DISPlay:WINDow:TRACe:Y[:SCALe]:PDIVision?
Title: Scale Resolution Per Division
Description: Sets the scale per division for the y-axis. The units change from dB/div
to % when EVM is the y-axis value. The resolution per division value is
maintained separately for each measurement.
Parameter: <value>
Default Value: Spectral Flatness: 1 dB/div
EVM vs. SubCarrier: 0.50%
EVM vs. Symbol: 0.50%
All others: 10dB/div
Default Unit: Current active amplitude unit
Range: EVM vs. SubCarrier: 0.1 % to 10 %
EVM vs. SubCarrier: 0.1 % to 10 %
All others: 1 dB to 15 dB
:DISPlay:WINDow:TRACe:Y[:SCALe]:TOP <amplitude>
:DISPlay:WINDow:TRACe:Y[:SCALe]:TOP?
Title: Y Axis Max
Description: Sets the maximum value of the Y axis. Note that this command is
available only in the Spectral Flatness and EVM vs. Symbol/Sub-carrier
views.
Parameter: <amplitude>
Default Value: Spectral Flatness: 5dB
EVM vs. Symbol: 5%
EVM vs. Sub-carrier: 5%
Default Unit: Current active amplitude unit
Range: Spectral Flatness: –5 to 5
EVM vs. Symbol: 1% to 100%
EVM vs. Sub-carrier: 1% to 100%
Front Panel Access: Amplitude, Y Axis Max

Table of Contents