VNA Commands 5-2 :CALCulate Subsystem
S412E PM PN: 10580-00319 Rev. N 5-19
:CALCulate<Tr>:LIMit:UPPer:X <x-parameter>
:CALCulate<Tr>:LIMit:UPPer:X?
Description: Moves the upper limit of the given trace <Tr> on the x-axis to the
given value. <Tr> is the trace number in the range 1 to 4. If no trace
number is specified, then the <Tr> parameter defaults to trace
number 1. <x-parameter> is defined in the given trace current x-axis.
The unit given with the <x-parameter> must correspond to the given
trace domain type. If no unit is specified with the <x-parameter> then
the default unit will be used. The set version of the command will
change the Move Limit on the front panel to Limit if it is currently set to
Point and set the given trace as the active trace. The query version of
the command returns the location of the given trace upper limit point on
the x-axis followed by the unit. If an error occurs, such as limit not ON,
the query version of the command returns an error code of 400. Limit
line must be on for the command to be valid. Use the command
:CALCulate:LIMit:TYPE to set the currently active limit line.
Cmd Parameter: <NRf> <x-parameter> (hertz, meters, feet)
Query Response: <NR3> <x-parameter> (hertz, meters, feet)
Default Units: Hz for Frequency domain,
Meters or Feet for distance domain.
Example: To move the trace 4 upper limit to 5000 Hertz (trace 4 in frequency
domain):
:CALCulate4:LIMit:UPPer:X 5000
OR to 500 MHz:
:CALCulate4:LIMit:UPPer:X 500 MHz
To move the trace 1 upper limit to 5 feet (trace 1 in distance domain
with current distance unit in meter):
:CALCulate:LIMit:UPPer:X 5 FT
OR to 4 Meter
:CALCulate1:LIMit:UPPer:X 4 M
:CALCulate:LIMit:UPPer:X 4
Related Command: :CALCulate:LIMit:TYPe
:CALCulate<Tr>:LIMit:UPPer:Y
Front Panel Access: Shift 6 (Limit), Limit Edit, Limit X

Table of Contents