LTE Commands 9-3 :CONFigure Subsystem
S412E PM PN: 10580-00319 Rev. N 9-7
:CONFigure:RF SUMMary|SPECtrum|ACLR|SEM
Title:
Select RF Measurements
Description:
This command configures RF measurements. It disables any other
active measurements. None of the instrument parameters are changed
by the execution of this command. Sets the instrument to single sweep
mode (:INITiate:CONTinuous OFF).Measurement settings can be
modified by using the [:SENSe] commands before initiating a
measurement.
Set measurement to one of the RF measurement screens. This can be
one of:
SUMMary: RF measurement summary screen.
SPECtrum: RF Channel Spectrum measurement screen.
ACLR: ACLR measurement view.
SEM: Spectral Emission Mask measurement.
Parameter:
SUMMary|SPECtrum|ACLR|SEM
Front Panel Access:
Measurements, RF, (Channel Spectrum, ACLR, Spectral Emission
Mask, RF Summary)
:CONFigure SUMMary
Title:
Set Measurement to LTE Summary
Description:
Sets the measurement to LTE Summary. It disables any other active
measurements. None of the instrument parameters are changed by the
execution of this command. (:INITiate:CONTinuous OFF).
Measurement settings can be modified by using the [:SENSe]
commands before initiating a measurement.
Parameter:
SUMMary
Parameter Type:
<char>
Front Panel Access:
Measurements, LTE Summary