P25 Phase 1 Commands 10-13 [:SENSe] Subsystem
S412E PM PN: 10580-00319 Rev. N 10-39
[:SENSe]:DM:PATTern 1011hz|O.153|VOICe|CTRLchan
[:SENSe]:DM:PATTern?
Description: Sets the receiver pattern type. Please note that setting the Rx Pattern
will restart the sweep.
Cmd Parameters: 1011hz|O.153|VOICe|CTRLchan
Query Parameters: NA
Range: 1011hz|O.153|VOICe|CTRLchan
Default Value: 1011hz
Default Unit: NA
Example: To set the modulation type to voice:
:DM:PATTern VOICe
Front Panel Access: Setup, Rx Pattern
[:SENSe]:FREQuency:CENTer <value>
[:SENSe]:FREQuency:CENTer?
Description: Sets the receiver center frequency. Please note that setting the center
frequency will restart the sweep
Cmd Parameters: <value>
Query Parameters: NA
Range: For 1.6 GHz Model: 100000 Hz to 1600000000 Hz
For 6 GHz Model: 100000 Hz to 6000000000 Hz
Default Value: 800000000 Hz
Default Unit: Hz
Example: To set the center frequency to 145 MHz:
:FREQuency:CENTer 145000000
Front Panel Access: Frequency, Rx Freq