14-7 :MEASure Subsystem DMR 2 Commands
14-18 PN: 10580-00319 Rev. N S412E PM
Note: The squelch setting [:SENSe]:DM:SQUelch will blank out (--)
all summary measurements on the instrument display except for
Received Pwr when the received power level is lower than the squelch
power setting. The received power level is also affected by the Rx Power
Offset setting. The query command will still return values even if the
instrument display is blanked out.
Cmd Parameters: NA
Query Parameters: NA
Range: NA
Default Value: NA
Default Unit: NA
Example: To measure DMR 2 Analyzer numerical data:
:MEASure:SIGAnalyzer?
Front Panel Access: NA