16-3 :DISPlay Subsystem NBFM Commands
16-8 PN: 10580-00319 Rev. N S412E PM
:DISPlay[:WINDow]:TRACe<Tr>:FORMat:SIGAnalyzer <graph type>
:DISPlay[:WINDow]:TRACe<Tr>:FORMat:SIGAnalyzer?
Description: Defines the graph type for the given trace <Tr>. <Tr> is the trace
number in the range 1 to 4. If no trace number is specified, then the
<Tr> parameter defaults to trace number 1. <Graph Type> is the
graph type to which the specified trace is set, and it must be one of the
following values:
SPECtrum|ASPEctrum|AWAVeform|SUMMary
The query version of this command returns “SPEC” if the specified trace
graph type is set to Spectrum, “ASPE” if set to Audio Spectrum, “AWAV”
if set to Audio Waveform, and “SUMM” if set to Summary.
Please note that this command only works when the current
measurement is set to NBFM Analyzer. Refer to the Related Command
below.
Cmd Parameters: <graph type>
Query Parameters: NA
Range: SPECtrum|ASPEctrum|AWAVeform|SUMMary
Default Value: Trace 1:Spectrum
Trace 2: Audio Spectrum
Trace 3: Audio Waveform
Trace 4: Summary
Default Unit: NA
Example: To set Trace 2 graph type to Audio Waveform:
:DISPlay:TRACe2:FORMat:SIGAnalyzer AWAVeform
Related Command: :CONFigure:SIGAnalyzer
Front Panel Access: Measurement, NBFM Analyzer, Graph Type
:DISPlay[:WINDow]:TRACe<Tr>:SELect
Description: Selects the given trace, <Tr>, as the active trace. <Tr> is the trace
number in the range 1 to 4 for NBFM Analyzer. If no trace number is
specified, then the <Tr> parameter defaults to trace number 1.
Cmd Parameters: NA
Query Parameters: NA
Range: NA
Default Value: TRAC1
Default Unit: NA
Example: To set trace 2 as the active trace:
:DISPlay:TRACe2:SELect
Front Panel Access: Measurement, NBFM Analyzer, Active Graph

Table of Contents