EasyManua.ls Logo

Anritsu LMR Master S412E - Page 599

Anritsu LMR Master S412E
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NBFM Commands 16-13 [:SENSe] Subsystem
S412E PM PN: 10580-00319 Rev. N 16-49
[:SENSe]:FREQuency:COUPling:OFFSet <value>
[:SENSe]:FREQuency:COUPling:OFFSet?
Description: Sets the frequency coupling offset. If frequency coupling is on, the
Tx frequency will automatically trail the Rx frequency by this amount.
Please note that the instrument will prevent any coupling offset setting
that will make the Tx frequency go beyond the min/max values.
The query returns the current coupling offset in Hz.
Cmd Parameters: <Value>
Query Parameters: NA
Range: -1000000000 Hz to 1000000000 Hz
Default Value: 0 Hz
Default Unit: Hz
Example: To set coupling offset to 200 MHz:
:FREQuency:COUPling:OFFSet 200000000
Front Panel Access: Frequency, Coupling Offset
[:SENSe]:FREQuency:SPAN 12.5|25|50
[:SENSe]:FREQuency:SPAN?
Description: Sets the span of the Spectrum display in NBFM Analyzer measurement
mode.
Note: Span value is set and returned in kHz.
Cmd Parameters: 12.5|25|50
Query Parameters: NA
Range: 12.5|25|50
Default Value: 25
Default Unit: kHz
Example: To set the span to 50 kHz:
:FREQuency:SPAN 50
Front Panel Access: Frequency, Span

Table of Contents

Related product manuals