4-10 :READ Subsystem Spectrum Analyzer Commands
4-36 PN: 10580-00319 Rev. N S412E PM
:READ:CHPower?
Title: Read Channel Power/Density
Description: Triggers a new channel power measurement and returns the results:
channel power and channel power density. It is a combination of the
commands :ABORT; :INITiate; :FETCh:CHPower? The channel power
measurement must be the active measurement (specified by the
command :CONFigure:CHPower). The current measurement can be
queried using the command :CONFigure?
Data is returned as 2 comma-separated values: channel power, channel
power density.
Default Unit: Current amplitude units
Related Command: :READ:CHPower:CHPower?
:READ:CHPower:DENSity?
:CONFigure
:READ:CHPower?
Title: Read Channel Power
Description: Triggers a new channel power measurement and returns the results. It
is a combination of the commands :ABORT; :INITiate;
:FETCh:CHPower? The channel power measurement must be active.
The current measurement can be queried using :CONFigure?
Default Unit: dBm
Related Command: :CONFigure:RF ACLR
:READ:OBWidth?
Title: Read Occupied Bandwidth
Description: Triggers a new occupied bandwidth measurement and returns the
results: occupied bandwidth, percent of power and dB down. It is a
combination of the commands :ABORT; :INITiate; :FETCh:OBWidth?
The occupied bandwidth measurement must be the active measurement
(specified by :CONFigure:OBWidth). The current measurement can be
queried using the :CONFigure?
Data is returned as 3 comma-separated values: occupied bandwidth,
percent of power, and dB down.
Default Unit: OBW in Hz, Percent of Power in %, dB Down in dB
Related Command: :CONFigure