1-9
1.4 Specifications
Table 1-6 Standard Specifications (Continued)
MF2414B
12
12.1
12.2
12.3
13
Auto/Manual measurement
Auto
(CW measurement)
(Burst measurement)
Manual
(CW measurement)
Manual
(Burst measurement)
Sample rate
Item
FM tolerance : 35 MHz
p-p
Acquisition time : 50 ms or less
FM tolerance : 35 MHz
p-p
Acquisition time : Measured carrier frequency: 1 GHz, Level: 0dBm
Acquisition time T
ACQ
= T
ACQ1
+ T
ACQ2
T
ACQ1
from Table A
T
ACQ2
= 4 ×{(T
p
+200 us) × K}
K: from Table B
T
p
: pulse repetition period
Table A Pulse Repetition Period T
p
vs. T
ACQ1
Table B Gating Time T
G
vs. K
Table C Trial Data Gate Time T
G
=100 us: k=100
Input tolerance : ±30 MHz (0.6 to 1 GHz)
±40 MHz (≥1 GHz)
Acquisition time : ≤15 ms
Input tolerance range : ±30 MHz (0.6 to 1 GHz) ……Pulse Width Wide Only
±20 MHz (≥1 GHz ) ……Pulse Width Narrow
±40 MHz (≥1 GHz ) ……PulseWidth Wide
Acquisition time : ≤15 ms
(pulse repetition period < 1 ms)
Auto : 10 ms to 10 s (1-2-5step), Hold
Manual : 1 ms to 10 s (1-2-5step), Hold
MF2412B MF2413B
Pulse Repetition Period T
p
200 us to 400 us
400 us to 600 us
600 us to 800 us
800 us to 1 ms
Acquisition time (max.) T
ACQ
1790 ms
1870 ms
1950 ms
2030 ms
Pulse Repetition Period T
p
1 us < T
p
≤ 1 ms
1 ms < T
p
≤ 10 ms
10 ms < T
p
≤ 100 ms
T
ACQ1
1.1 s
1.6 s
6.1 s
Gating Time T
G
1 us ≤ T
G
≤ 10 us
10 us < T
G
≤ 100 us
100 us < T
G
≤ 100 ms
K
10000
100
5