Appendix E: Technical Specification 219 (258)
E.3.2 Power Consumption
TheAnybus CompactCom 40 PROFINET IRT is designed to fulfil the requirements of a Class B
module. The current hardware design consumes up to 390 mA
TheAnybus CompactCom 40 PROFINET IRT FO is designed to fulfil the requirements of a
Class C module. The current hardware design consumes up to 740 mA
In line with HMS policy of continuous product development, we reserve the right to change the
exact power requirements of this product without prior notification. However, in any case, the
Anybus CompactCom 40 PROFINET IO will remain as a Class B module.
E.4 Environmental Specification
Consult the Anybus CompactCom 40 Hardware Design Guide for further information.
E.5 EMC Compliance
Consult the Anybus CompactCom 40 Hardware Design Guide for further information.
E.6 Fiber Optics Compliance (MAU type Compliance)
The optical interface of theAnybus CompactCom 40 PROFINET IRT is compliant with the non
IEEE802.3 MAU type POF.
The supported cables are stated in the PI document PROFINET Cabling and Interconnection
Technology;
for (SI-POF/PCF):
Physical Layer Medium Dependent Sublayer on 650 nm Fiber Optics
PROFIBUS & PROFINET International Order No: 2.432
Anybus
®
CompactCom
™
40 PROFINET IRT Network Guide SCM-1202-023 EN 1.8