Host Application Objects 174 (258)
14.5 Sync Object (EEh)
Category
Extended
Object Description
This object contains the host object sync settings.
The implementation of this object is optional. If it is not implemented the Anybus CompactCom 40 PROFINET
IRT can not be used for a synchronous application.
If there is any problem with the configuration of the sync functionality as a whole, the application must indicate
this in the application status register. The Anybus CompactCom will then change states and inform the prob-
lem to the PROFINET IO Controller, see Application Status Register, p. 208.
See also ...
• Anybus CompactCom 40 Software Design Guide, “Sync”
• Anybus CompactCom 40 Software Design Guide, “Sync Object”
Supported Commands
Object: Get_Attribute
Instance: Get_Attribute
Set_Attribute
Object Attributes (Instance #0)
(Consult the general Anybus CompactCom 40 Software Design Guide for further information.)
Anybus
®
CompactCom
™
40 PROFINET IRT Network Guide SCM-1202-023 EN 1.8