Figure 91. Inserting a Battery
Charger LED Status Indications
There are two status indicators for each battery bay. Table 36 lists the possible indicator
conditions and their meanings.
Table 35. Status Indicator Conditions
Fully Charged Battery LED (green)
On steady with external power applied
and battery fully charged (>95%).
Off with external power disconnected or
battery charge <95%.
On steady with external power applied
and battery charging.
Flashing 1 sec on/1 sec off with external
power applied and battery temperature
above or below maximum limits.
Flashing 1 sec on/1 sec off with external
power applied, temperature in limits,
and other battery charging (serial
charging).
Fault LED (red) On steady when fault in power system
is detected (over voltage, under voltage,
excessive current, charger circuit failure
or battery circuit failure).
Off when fault is corrected.