Details on the recommended screw gun type and required sockets for panel installation.
Information on types of snips needed for cutting metal panels and flashings.
Description and application of butyl mastic tape for water infiltration prevention in flashing.
Preparation steps for new roof installations, including deck cleaning and underlayment application.
Considerations for reroofing over existing roofing, including checks for damage and substrate suitability.
Illustrations showing correct, under, and over driving techniques for gasketed fasteners.
Installation details for the standard eave flashing (E1).
Installation details for the vented eave flashing.
Installation details for the vented gutter flashing, including attachment and sealing.
Details for installing the side portion of the skylight flashing.
Details for installing the side portion of the chimney flashing, including the reglet component.
Details for installing the uphill side of the chimney flashing, including reglet and closure.
Details for installing the downhill side of the chimney flashing, including reglet and closure.
Detail showing the installation of C-Metal (C1) or Base Trim (B1) at window/door trim corners.
Details for C-Metal (C1) and Base Trim (B1) at the top and bottom of wall panels.
Installation details for inside corner trim (IC1, IC2) for wall panels.
Installation details for outside corner trim (OC1, OC2) for wall panels.