Light Gauge Metal Roof and Wall Panels InstallationAugust 2016 47
ASC Building Products
A Division of ASC Profiles LLC
3/8" HEM
3/8" HEM
3 1/2"
3 1/2"
4"
5/8"
3/8" HEM
1 1/8"
SYMMETRICAL
BUTYL MASTIC TAPE
ASC'S LIGHT
GAUGE WALL PANEL
3. #12 x 3/4" STITCH SCREW
OR
4. #14 x 7/8" LAP SELF DRILLER
@ 24" O.C. MAX
INSIDE CORNER (IC1)
1. #9 WOOD SCREW
OR
2. #14 WOOD SCREW
SEE ILLUSTRATION
ON PAGE 7
IC1
Procedures
Open framing shown. If installing over plywood,
use a #14 x 1" woodscrew for panel attachment.
• Nor-Clad
®
panel shown. When installing other Light
Gauge panels, use the Universal Inside Corner “IC2”.
In many situations, the last panel installed at the
corner will require that the panel be cut in width. Allow the
cut edge to be covered by the inside corner trim.
Wall Details
Inside Corner
IC2

Table of Contents