Light Gauge Metal Roof and Wall Panels InstallationAugust 2016 9
ASC Building Products
A Division of ASC Profiles LLC
2"
1 7/8"
3/4"
1/2"
1/2"
3/8" HEM
7"
7"
2 1/8"
UNIVERSAL RIDGE (R1)
2. #14 WOOD SCREW
SEE ILLUSTRATION
ON PAGE 7
TOP POLYETHYLENE CLOSURE SET
IN SEALANT ALL AROUND
(SEE PROCEDURES)
ASC'S LIGHT
GAUGE ROOFING
3. #12 x 3/4" STITCH SCREW
OR
4. #14 x 7/8" LAP SELF DRILLER
@ EACH RIB OR 8" O.C.
FOR CORRUGATED
3-3/4"
3-1/2"
1/2"
135º TYP.
3/8" HEM
2"
1 7/8"
3/4"
1/2"
1/2"
3/8" HEM
7"
7"
2 1/8"
UNIVERSAL RIDGE (R1)
2. #14 WOOD SCREW
SEE ILLUSTRATION
ON PAGE 7
TOP POLYETHYLENE CLOSURE SET
IN SEALANT ALL AROUND
(SEE PROCEDURES)
ASC'S LIGHT
GAUGE ROOFING
3. #12 x 3/4" STITCH SCREW
OR
4. #14 x 7/8" LAP SELF DRILLER
@ EACH RIB OR 8" O.C.
FOR CORRUGATED
3-3/4"
3-1/2"
1/2"
135º TYP.
3/8" HEM
Hip/Ridge Flashing
Procedures
Caulk the bottom and sides of the polyethylene
closure. Set the closure as shown above and caulk
the top. The closure is optional if the panel is turned
up and caulked at the sides near the rib.
Fasten the ridge cap using stitch screw at each rib
or 8" o.c. for corrugated.
Close the ends of the universal ridge cap by cutting
and folding material at each end. Fasten with rivets.
(see page 10)
Caulk, lap and rivet sequential ridge flashings.
(see page 44)
R1
R3
R4
Note: “R1” is a universal hip/ridge. A standard hip/ridge,
“R3 & R4”, is also available.
Note: The gable flashing must be installed prior to
installation of the ridge (see page 18).

Table of Contents