Page #51 background imageLoading...
Page #51 background image
TD 92644EN
User Manual
Ascom d81 DECT Handset
6 Alarm Operation
48
18 June 2018 / Ver. K
the handset receives a notification that the alarm has been received by the system. This
is a system dependent feature.
if configured, the ALS (see 6.5 Acoustic Location Signal on page 50) is activated after
the alarm has been sent, or a call is established to a predefined number (see 6.6
Automatic Call after Alarm on page 50).
NOTE: If the parameter "Silent alarm" is set, no ALS is triggered and no indication of an
alarm has been sent by the handset/received by the system is shown.
information about the handset’s location is sent along with an alarm, see 6.4 Alarm with
Location Information on page 49.
6.2 Man-Down and No-Movement Alarm
NOTE: Man-down and No-movement are not available when upgrading the product license
from d81 Messenger to d81 Protector. That is, it is only applicable for d81 Protector with the
No-movement/Man-down hardware variant.
Man-down alarm: If the handset is tilted 45 degrees
(default) or more for a preset time
(default 7 seconds), the Man-down alarm is triggered. The accuracy of the tilt is + or - 10
degrees.
No-movement alarm: If no movement is detected during a preset time (default 30 seconds),
the No-movement alarm is triggered.
When an alarm is triggered, the following occurs;
A Man-down warning. Cancel? or No- movement warning. Cancel? dialog window is
shown in the display, and a warning tone is also signalling during a period (default 7
seconds) before the alarm is sent.
To prevent the alarm from being sent and silencing the warning tone, do one of the
following:
- Press any key/button. The alarm is reset.
- Put the handset in a charger. The alarm is temporarily disabled indicated by that the
corresponding alarm icon is hidden. The alarm is enabled when removing it from the
charger.
- Press . A Delay MD/NV detection? dialog window appears. Disable the alarm
temporarily for a specified time by pressing "Yes". When the alarm is temporarily
disabled, the corresponding alarm icon flashes. NOTE: Requires that the parameters
"NM-MD extra delay used" and "NM-MD extra delay time" are set in the PDM/Device
Manager.
If no key/button is pressed during the warning tone, the alarm is sent. Depending on set
parameters, a beep/vibrator/LED signal confirms that the alarm has been sent.
An acoustic location signal (ALS) may be activated after the alarm has been sent, or a
call may be established to a predefined number. See 6.5 Acoustic Location Signal on
page 50, or 6.6 Automatic Call after Alarm on page 50.
Information about the handset’s location may be sent along with the alarm, see 6.4
Alarm with Location Information on page 49.
The Man-down alarm and No-movement alarm can temporarily be disabled during calls to
avoid sending false alarms when the user tilts the handset or does not move during the call.
If the Man-down alarm and No-movement alarm are disabled during calls, the
corresponding icons are not displayed, see the handset’s Configuration Manual.
See also 7.8.10 Alarm Settings on page 80.