• Input Trigger
1 Select input in the Input drop-down list. Only inputs defined in the I/O Setup are
available. Refer to 4.5 Input/Output Setup on page 18.
2 Enter (in seconds) the interval between repetitions in the Repetition Time text field.
Note that this field must be set to min.10 seconds even if no repetitions shall be
made.
3 Enter how many times the action shall be repeated in the Max. No. of Repetitions
text field. For no repetitions, enter '0'.
4 Click “Add”.
• Data Trigger
1 Enter data in the Data text field.
2 If the data is to be sent from a specific handset, enter handset No. in the Number
text field. Leave empty if any handset shall be able to send the data. Note that the
handset must be defined in Messaging Users.
Select Type of Action
1 Select type of action in the Actions drop-down list and click “Add”. Several actions
can be added.