What to do if ASP Laboratory Equipment says 'Cassette Expired' or 'Cassette Out of Date'?
J
Jared JacobsonSep 1, 2025
If the ASP Laboratory Equipment indicates that the cassette has expired, is out of date, or has already been used, load a new cassette. If the message persists, run diagnostics. If diagnostics fail, adjust or replace the delivery subsystem.
R
Richard WalkerSep 2, 2025
What to do if ASP sterrad NX Laboratory Equipment shows 'Door Sensor Fault'?
R
Rebecca PetersonSep 2, 2025
If the ASP Laboratory Equipment displays a door sensor fault, run diagnostics. You may need to troubleshoot or replace the door sensor.
T
Tracy FisherSep 3, 2025
What to do if ASP sterrad NX Laboratory Equipment displays 'Low Plasma Power'?
A
Andrew DonaldsonSep 3, 2025
If the ASP Laboratory Equipment displays a 'Low Plasma Power' message, run diagnostics to determine the cause of the power problem. If the diagnostics fail, replace the LFPS II power supply.
C
Caroline SteeleSep 3, 2025
What to do if ASP sterrad NX displays 'Less Number of Cells Available'?
C
Christopher Dixon MDSep 3, 2025
If the ASP Laboratory Equipment indicates that there are fewer cells available or no cells found during start, it means the existing cassette is disposed because there are not enough cells for a cycle. Insert a new cassette. If the problem persists, run diagnostics. Adjust or replace the delivery subsystem if diagnostics fail.
D
Darrell BaldwinSep 4, 2025
What to do if ASP sterrad NX Laboratory Equipment displays 'Incorrect Cassette Type'?
J
jamesboydSep 4, 2025
If the ASP Laboratory Equipment ejects the cassette and displays 'Incorrect Cassette Type', insert a STERRAD NX Cassette. If the problem continues, run diagnostics. Adjust or replace the delivery subsystem if necessary.
T
Timothy JohnsonSep 5, 2025
What to do if ASP sterrad NX displays 'Vaporizer Temperature' error?
G
Gabriela ParkerSep 5, 2025
If the ASP Laboratory Equipment displays an error related to the vaporizer temperature (has not risen, too high, or too low), run diagnostics to determine if a sensor or heater has failed. Troubleshoot or replace the failed component.
A
Amanda GrossSep 6, 2025
What to do if ASP sterrad NX displays 'Pressure Out of Range'?
S
Samuel DavisSep 6, 2025
If the ASP Laboratory Equipment displays a 'Pressure Out of Range' error (high or low), verify the load is dry and not outgassing. Start a new cycle. If the pressure cannot be maintained during vacuum, run diagnostics and replace any failed components.
D
dmillsSep 6, 2025
What to do if ASP sterrad NX Laboratory Equipment displays 'Cannot Light Plasma'?
W
william39Sep 7, 2025
If the ASP Laboratory Equipment displays 'Cannot Light Plasma', inspect the load. If the load is touching the electrode, reposition the load and start a new cycle. If the problem persists, run diagnostics. If diagnostics fail, troubleshoot or replace the LFPS II power supply.