EasyManua.ls Logo

ATEQ D520 - Page 73

ATEQ D520
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 – Functions of the instrument
UM-22100H-U User manual ATEQ D520 Page 63/122
2.1.3. 22) Stamping function
This option is used to activate a pneumatic output which marks the part (for example
using a pneumatic cylinder).
Parameters can be set for the conditions and duration of marking.
This option requires two electrical outputs:
9 an internal one for the internal cabling on the pneumatic output,
9 an external one for "customer" cabling
One of the pneumatic outputs on the automatic connectors is used.
The output is activated at the end of test time for the programmed hold time.
Use the following procedure to use the inking function.
First, in the
CONFIGURATION menu,
confirm the STAMPING
function.
CONFI/
EXTEND
ED
MENU
FILL MODE : Yes
AUTO CONNECT : Yes
STAMPING : Yes
In the program's
PARAMETERS/FUNCTIONS
menu, confirm the STAMPING
function.
PARAM/P
r
001/FUNCTION
AUTO CONNECT : No
STAMPING : Yes
MINI-VALVE : Yes
Set the inking hold value (can
be set between 0 and 650
seconds).
P
r
001/FU
NCT/
STAMPING
MAINTAIN : 00.5 s
ALL : No
OK : Yes
Then select the inking
conditions from those offered.
P
r
001/FONCT/
STAMPING
MAINTAIN : 00.5 s
ALL : Non
OK : Oui
When the instrument possesses this option, the internal and external valve codes 1 are
no longer available.