Hydraulic settings DC 200
The combination of oil flow rate and operating pressure must not exceed the nominal power of the Drum
Cutter.
Operating pressure (bar)
Oil flow rate (l/min)
Rotational speed (rpm)
100 20 30 40
400 80
120 160 200 240 280
50
50
100
200
300
150
250
350
60 70
12 kW
18 kW
Oil flow rate [l/min] =
Nominal power [kW] x 600
Operating pressure [bar]
Operating pressure [bar] =
Nominal power [kW] x 600
Oil flow rate [l/min]
max. power range
Recommended power range
recommended
Oil flow rate (l/min)
Operating pressure (bar)
Note:
The transverse drum cutter must not be operated simultaneously at maximum operating pressure and
maximum oil flow rate, otherwise the permissible nominal power is exceeded. The transverse drum cutter
must be operated within the recommended power range.
The higher the operating pressure the higher the cutting force and torque.
The higher the oil flow the higher the rotational speed and pick speed.
163
44
189
38
225
32
277
26
Safety and operating instructions DC 200, 400, 600, 1000, 1200, 2000, 2100, 2900
68 © Construction Tools GmbH | 3390 5192 01 | 2016-12-01