Hydraulic settings DC 2000
The combination of oil flow rate and operating pressure must not exceed the nominal power of the Drum
Cutter.
Operating pressure (bar)
Oil flow rate (l/min)
Rotational speed (rpm)
30025050
200 10 30 50 7040
60
80 90 100
110
50
100
200
300
150
250
350
150 350200100
Oil flow rate [l/min] =
Nominal power [kW] x 600
Operating pressure [bar]
Operating pressure [bar] =
Nominal power [kW] x 600
Oil flow rate [l/min]
78 kW
110 kW
max. power range
Recommended power range
Note:
The transverse drum cutter must not be operated simultaneously at maximum operating pressure and
maximum oil flow rate, otherwise the permissible nominal power is exceeded. The transverse drum cutter
must be operated within the recommended power range.
The higher the operating pressure the higher the cutting force and torque.
The higher the oil flow the higher the rotational speed and pick speed.
Oil flow rate (l/min)
180
260
195
240
212
220
234
200
recommended
Operating pressure (bar)
DC 200, 400, 600, 1000, 1200, 2000, 2100, 2900 Safety and operating instructions