Hydraulic settings DC 600
The combination of oil flow rate and operating pressure must not exceed the nominal power of the Drum
Cutter.
Operating pressure (bar)
Oil flow rate (l/min)
Rotational speed (rpm)
0 25
50
20
0 40 60 80 100
120 140
160
50
100
200
300
150
250
350
150
12575 100
Oil flow rate [l/min] =
Nominal power [kW] x 600
Operating pressure [bar]
Operating pressure [bar] =
Nominal power [kW] x 600
Oil flow rate [l/min]
30 kW
45 kW
max. power range
Recommended power range
Note: 
The transverse drum cutter must not be operated simultaneously at maximum operating pressure and 
maximum oil flow rate, otherwise the permissible nominal power is exceeded. The transverse drum cutter
must be operated within the recommended power range.
The higher the operating pressure the higher the cutting force and torque.
The higher the oil flow the higher the rotational speed and pick speed.
Oil flow rate (l/min)
171
105
200
85
240
75
300
60
recommended
Operating pressure (bar)
Safety and operating instructions DC 200, 400, 600, 1000, 1200, 2000, 2100, 2900
70 © Construction Tools GmbH | 3390 5192 01 | 2016-12-01