Hydraulic settings DC 400
The combination of oil flow rate and operating pressure must not exceed the nominal power of the Drum
Cutter.
Operating pressure (bar)
Oil flow rate (l/min)
Rotational speed (rpm)
0 20 40
200 80
60 80 100 120 140 160 160
50
100
200
300
150
250
350
60 80 100
20 kW
30 kW
Oil flow rate [l/min] =
Nominal power [kW] x 600
Operating pressure [bar]
Operating pressure [bar] =
Nominal power [kW] x 600
Oil flow rate [l/min]
max. power range
Recommended power range
recommended
Note:
The transverse drum cutter must not be operated simultaneously at maximum operating pressure and
maximum oil flow rate, otherwise the permissible nominal power is exceeded. The transverse drum cutter
must be operated within the recommended power range.
The higher the operating pressure the higher the cutting force and torque.
The higher the oil flow the higher the rotational speed and pick speed.
Oil flow rate (l/min)
171
70
200
62
240
50
300
40
Operating pressure (bar)
DC 200, 400, 600, 1000, 1200, 2000, 2100, 2900 Safety and operating instructions
© Construction Tools GmbH | 3390 5192 01 | 2016-12-01
Original instructions
69