DL250–1 Memory
Type
QTY (Dec.) PLC Range (Octal)
Modbus Address
Range (Decimal)
Modbus Data Type
For Discrete Data Types ............. Convert PLC Addr. to Dec. + Start of Range + Data Type
Inputs (X) 512 X0 – X777 2048 – 2560 Input
Special Relays (SP) 512
SP0 – SP137
SP320 – SP717
3072 – 3167
3280 – 3535
Input
Outputs (Y) 512 Y0 – Y777 2048 – 2560 Coil
Control Relays (C) 1024 C0 – C1777 3072 – 4095 Coil
Timer Contacts (T) 256 T0 – T377 6144 – 6399 Coil
Counter Contacts (CT) 128 CT0 – CT177 6400 – 6527 Coil
Stage Status Bits (S) 1024 S0 – S1777 5120 – 6143 Coil
For Word Data Types .............................. Convert PLC Addr. to Dec. + Data Type
Timer Current Values (V) 256 V0 – V377 0 – 255 Input Register
Counter Current Values (V) 128 V1000 – V1177 512 – 639 Input Register
V-Memory, user data (V)
3072
4096
V1400 – V7377
V10000 – V17777
768 – 3839
4096 – 8191
Holding Register
V-Memory, system (V) 256 V7400 – V7777 3480 – 3735 Holding Register
DL260 Memory Type QTY (Dec.) PLC Range (Octal)
Modbus Address
Range (Decimal)
Modbus Data Type
For Discrete Data Types ............. Convert PLC Addr. to Dec. + Start of Range + Data Type
Inputs (X) 1024 X0 – X1777 2048 – 3071 Input
Remote Inputs (GX) 2048 GX0 – GX3777 3840 – 18431 Input
Special Relays (SP) 512 SP0 – SP777 3072 – 3583 Input
Outputs (Y) 1024 Y0 – Y777 2048 – 3071 Coil
Remote Outputs (GY) 2048 GY0 – GY3777 18432 – 20479 Coil
Control Relays (C) 2048 C0 – C377 3072 – 5159 Coil
Timer Contacts (T) 256 T0 – T177 6144 – 6399 Coil
Counter Contacts (CT) 256 CT0 – CT177 6400 – 6655 Coil
Stage Status Bits (S) 1024 S0 – S777 5120 – 6143 Coil
For Word Data Types ............................. Convert PLC Addr. to Dec. + Data Type
Timer Current Values (V) 256 V0 – V177 0 – 255 Input Register
Counter Current Values (V) 256 V1000 – V1177 512 – 767 Input Register
V-Memory, user data (V) 14.6K
V400 – V777
V1400 – V7377
V10000 – V35777
1024 – 2047 Holding Register
V-Memory, system (V)
256
1024
V7400 – V7777
V36000 – V37777
3480 – 4095
15360 – 16383
Holding Register

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Automationdirect.com DirectLOGIC DL205 Series and is the answer not in the manual?

Automationdirect.com DirectLOGIC DL205 Series Specifications

General IconGeneral
BrandAutomationdirect.com
ModelDirectLOGIC DL205 Series
CategoryController
LanguageEnglish

Related product manuals