[no] snmp-server notification-control {pethPsePortOnOffNotification
| pethMainPowerUsageOnNotification |
pethMainPowerUsageOffNotification}
Variable definitions
The following table describes the parameters for the snmp-server notification-control
command.
Variable Value
pethPsePortOnOffNotification |
pethMainPowerUsageOnNotification |
pethMainPowerUsageOffNotification
Specifies a notification type
no Disables the traps for the PoE function
Displaying PoE configuration
You can display the status for the PoE configuration on the PWR+switch.
Displaying the current PoE configuration
Display the current PoE configuration of the PWR+switch, and settings for each PoE port.
Procedure
1. Enter Privileged EXEC mode:
enable
2. At the command prompt, enter the following command:
show poe-main-status [unit <1–8>]
Example
The following figure provides a sample output of the show poe-main-status command.
switch#show poe-main-status
PoE Main Status - Stand-alone
---------------------------
Available DTE Power : 370 Watts
DTE Power Status : Normal
DTE Power Consumption : 0 Watts
DTE Power Usage Threshold : 80 %
PD Detect Type : 802.3at and Legacy
Power Source Present : AC Only
AC Power Status : Present
DC Power Status : Not Present
Displaying PoE configuration
July 2015 Getting Started with Avaya ERS 3500 Series 105