4. In the work area, click the Stack Numbering tab.
5. In the unit row, double-click the cell in the New Unit Number column.
6. Select a value from the list.
7. On the toolbar, click Apply.
A warning message appears indicating that initiating the renumbering of switch units in a
stack results in an automatic reset of the entire stack.
Stack Numbering field descriptions
The following table describes the fields on the Stack Numbering tab.
Name Description
Current Unit Number Identifies the current switch numbering sequence
New Unit Number Identifies the updated switch numbering sequence
Displaying stored content
Use this procedure to display information about files stored on the switch or stack.
Procedure
1. In the navigation tree, click Edit.
2. From the Edit tree, click Chassis.
3. From the Chassis tree, click Switch/Stack.
4. In the work area, click the Store Content tab.
Store Content field descriptions
The following table describes the fields on the Store Content tab.
Name
Description
Indx Displays the file index number
Type Displays the file storage type
CurSize Displays the current size of the file storage
CntntVer Displays the file version in storage
Filename Displays file names for the stored content
Global AES configuration using EDM
Use the information in this section to configure Avaya Energy Saver (AES) for an single switch or a
stack.
Configuring the switch using EDM
140 Getting Started with Avaya ERS 3500 Series July 2015