EasyManua.ls Logo

Avaya 3500 series - Enabling or Disabling UTC Timestamp in ACLI Show Command Outputs; Setting Boot Parameters Using ACLI

Avaya 3500 series
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Offset: 60 minutes.
Daylight saving time is disabled
Enabling or disabling UTC timestamp in ACLI show command
outputs
Use this procedure to enable or disable the display of the UTC timestamp in ACLI show command
outputs. The default, the timestamp state is disabled.
Procedure
1. Enter Global Configuration mode:
enable
configure terminal
2. To enable the display of the UTC timestamp, enter the following command:
cli timestamp enable
3. To disable the display of the UTC timestamp, enter the following command:
no cli timestamp enable
Setting boot parameters using ACLI
You can restart the switch and configure BootP using ACLI.
Performing a soft-start of the switch
Use this command to perform a soft-start of the switch.
Procedure
1. Enter Privileged EXEC mode:
enable
2. To perform a soft-start of the switch, enter the following command:
boot [default]
Variable definitions
The following table describes the parameters for the bootp command.
Variable
Value
default Restores switch to factory-default settings after
restarting.
Configuring the switch using ACLI
76 Getting Started with Avaya ERS 3500 Series July 2015