1 Migrating to the Avaya S8700 or S8710 Media Server
Basic migration steps
28 Migrating to the Avaya S8700 or S8710 Media Server
June 2004
Basic migration steps
When migrating from DEFINITY platforms:
• Install the Avaya S8700 or S8710 Media Servers and, if Avaya supplied, the Ethernet switch(es),
and uninterruptible power supplies (UPSs) in the 4-post, 19-inch rack as described in the Quick
Start for Hardware Installation: Avaya S8700 or S8710 Media Server (555-245-703).
• Replace Tone-Clock circuit packs with IPSI circuit packs in existing expansion port networks
(when reusing SCCs or MCCs).
• Convert the existing processor control carrier/cabinet to an expansion control carrier/cabinet.
(when reusing cabinets).
• Replace the Tone-Clock, Processor, or both circuit packs with the IPSI circuit pack in the existing
port network.
• S8700 MC: If high or critical reliability, replace the second control carrier/cabinet with a port
carrier/cabinet (when reusing SCCs or MCCs).
• S8700 IP: Move circuit packs to G650 Media Gateway (when not reusing cabinets).
• Connect the media servers to the media gateways.
• Enable control of the IPSIs, switching control to the S8700 or S8710 Media Servers.
• Complete the post-migration administration.
When migrating from S8500 or S8700 Media Servers:
• Install the Avaya S8710 Media Servers either
— in a 19-inch, 4-post rack on a 2-post rack. as described in the Quick Start for Hardware
Installation: Avaya S8700 or S8710 Media Server (555-245-703).
— on a pullout shelf attached to a 2-post rack.
• Back up all the system files from both S8700 Media Servers to the customer’s network using the
Linux Migration - Backup/Restore link on the Maintenance Web Interface.
• Install the R2.1 software on the S8710 Media Servers.
• Restore the system files from the customer’s network to both S8710 Media Servers using the
Linux Migration - Backup/Restore link.
• Connect the duplication cables after restoring files to the second media server.
NOTE:
If moving Ethernet switch(es) and UPSs to the 4-post rack, do it here before the cutover.
• Connect the control network Ethernet cables to the new S8710 Media Servers, standby media
server first.