50 Migrating to the Avaya S8700 or S8710 Media Server
June 2004
S8700 MC:
S8700 IP:
2 Set the Enable Operation of IPSI Duplication? field to y.
3 Press Enter to effect the changes.
Setting alarm activation level
1
Type change system-parameters maintenance and press Enter.
2 In the CPE Alarm Activation Level field, select none (default), warning, minor, or major,
depending on the level the customer wants.
change system-parameters duplication Page 1 of 1
DUPLICATION RELATED SYSTEM PARAMETERS
Enable Operation of PNC Duplication? y
Enable Operation of IPSI Duplication? y
change system-parameters duplication Page 1 of 1
DUPLICATION RELATED SYSTEM PARAMETERS
Enable Operation of IPSI Duplication? y
change system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Start Time: 22 : 00
Stop Time: 06 : 00
Save Translation: daily
Update LSPs When Saving Translations: y
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no