Migrating from a DEFINITY ECS R or SI
96 Migrating to the Avaya S8700 or S8710 Media Server
June 2004
Removing the circuit packs
CAUTION:
Always wear an antistatic wrist strap when removing circuit packs and associated cables.
1 Remove all circuit packs. Store the circuit packs in static-proof packaging.
2 Remove all reusable equipment and cables. See Table 10, List of reusable equipment and cables,
on page 96.
3 Repeat for carriers/cabinets B, C, D, and E.
Repeat Powering down the cabinets
on page 95 through Removing the circuit packs on page 96 for each
MCC or SCC.
Table 10: List of reusable equipment and cables
Reusable Circuit Pack
Associated
Equipment/Cables Notes
TN799DP C-LAN TN2302AP Amphenol
Adapter
CAT5 cable with DW8
connectors
Provides 100 Mbps
connectivity
Can use adapter and cable
from TN799B/C, but they
only provide 10 Mbps
connection.
TN2302AP IP Media Processor TN2302AP Amphenol
Adapter
CAT5 cable with DW8
connectors
Provides 100 Mbps
connectivity
TN2501AP VAL Announcement Backplane Adapter
CAT5 cable with DW8
connectors
Station adapter 258A adapter
Station adapter 356A adapter
DS1Interface Trunk
TN464GP/TN2464BP
TN767E
TN2207
TN2313AP
120A CSU module
700A DS1 loop-back jack
H600-383 cable
DW8A-DE cord
Trunks and lines I/O cables
Other 10 AWG (#25) wire to
coupled bonding conductor