3 Migrating from an S8700 Media Server to an S8710 Media Server
On the S8700 Media Server
146 Migrating to the Avaya S8700 or S8710 Media Server
June 2004
Record all busyouts
1 Type display errors and press Enter. Look for type 18 errors and record any trunks that are
busied out, so you can return them to their busied-out state after the upgrade.
Check clock synchronization
1 Type status sync and press Enter to verify that the clock synchronization is good.
2 Make sure the Switching Capabilities field shows enabled.
NOTE:
Because of a change in Release 1.3 of the Avaya Communication Manager, you do not
need to disable Terminal Translation Initialization (TTI) before an upgrade or migration or
enable it afterwards.
Disable scheduled maintenance
To prevent scheduled daily maintenance from interfering with the upgrade:
1 Type change system-parameters maintenance and press Enter.
2 If scheduled maintenance is in progress, set the Stop Time field to 1 minute after the current time.
or
If scheduled maintenance is not in progress, set the
Start Time field to a time after the upgrade
will be completed.
For example, if you start the upgrade at 8:00 P.M. and the upgrade takes 90 minutes, set the
Start
Time
field to 21:30.
Busyout MMI circuit packs (duplicated control
only)
CAUTION:
Multimedia-to-voice station calls are not preserved on an upgrade. Failure to busy-out the
TN787 Multimedia Interface (MMI) circuit packs results in unusable TN787 and TN787
Multimedia Voice Conditioner ports.
1 Type display system-parameters customer-options and press Enter. On screen 2 or 3 under
the Multimedia Call Handling (MMCH) options, check the
Basic and Enhanced fields.
2 If either the Basic or Enhanced field is y, type list configuration all and press Enter to locate all
MMI (TN787) circuit packs.
3 If there are MMI circuit packs, type busyout board UUCSS and press Enter for each MMI
circuit pack. The variable
UUCSS is the slot location (UU = cabinet, C = carrier, SS = slot).