Converting a processor port network to a port network (CMC)
Migrating to the Avaya S8700 or S8710 Media Server 99
June 2004
NOTE:
If customers are currently using the Audix feature on the S8100 Media Server, they need
to purchase a separate Audix system. The TN795 or TN2314 Processor circuit pack
containing the Audix feature is being replaced with a TN2312BP Internet Protocol Server
Interface (IPSI-2) circuit pack that does not have that feature. The existing processor
circuit pack must be returned to Avaya.
NOTE:
Customers also need to add an ED-1E568-70G1 DEFINITY Audix Slim board and a
TN2501AP Voice Announcement over LAN (VAL) circuit pack for announcements.
Converting the control cabinet to a port
network
To convert the control cabinet to a port network, you must
If CSI, remove the TN798 or TN2402 Processor circuit pack and replace the TN2182 Tone Clock
circuit pack with a TN2312BP Internet Protocol Server Interface (IPSI-2) circuit pack.
If S8100 Media Server, replace the TN795 or TN2314 Processor circuit pack with a TN2312BP
Internet Protocol Server Interface (IPSI-2) circuit pack.
Connect a CAT5 straight-through cable from the IPSI to the media server through the customers
network.
NOTE:
If replacing a TN795 Processor circuit pack, you may not need the TN744D/E Call
Classifier-Detector circuit pack. The TN2312BP Internet Protocol Server Interface (IPSI-
2) circuit pack has call classifier functionality; however, increased voice and data traffic
may require the TN744D/E Call Classifier-Detector circuit pack.
NOTE:
If you have a TN799C or earlier C-LAN circuit pack, you must replace it with a TN799DP
C-LAN circuit pack.
700060643 TN2302AP IP Media Processor circuit pack 1 or more
700055015 TN799DP C-LAN circuit pack (to replace TN799C) 1 or more
848525887 IP Media Processor adapter 1/MedPro
1/C-LAN
NA CAT5 cables 1/MedPro
1/C-LAN
106689516 TN771 Maintenance/Test circuit pack (optional) 1 or more
108772583 TN2501AP Voice Announcement over LAN circuit pack
(optional)
1
NA ED-1E568-70G1 (optional) 1