EasyManua.ls Logo

Avaya S8700 - Page 130

Avaya S8700
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
130
Installing the S8700 IP Connect
May 2002
Connections for 1 to 8 Out-of-Building Analog Telephones
8
7
1
9
10
11
13
14
12
crdfobt CJL 101396
2
4 4
6
6
5
33
Figure notes
1 Locally Engineered Cables and Equipment
2 Out-of-Building Wiring
3 25-Pair Connector
4 Multi-Pair Protector Units (Primary
Protectors with Heat Coils or Equivalent
with Sneak Current Protection)
5 356A Adapter
6 B25A Cable (Male to Female)
7 Out-Of-Building Analog Telephones
8 Part of Main Distribution
Frame (MDF)
9 Station Side
10 Media Gateway Side
11 White Field
12 Purple Field
13 Cross-Connect Jumpers
14 Tip and Ring Wires
15 To Analog Line Circuit Pack

Table of Contents