152
Installing the S8700 IP Connect
May 2002
3 Plug the battery cord into the power supply’s right rear receptacle. The rear receptacle is
indicated on the right label.
Install the Expanded Power Distribution Unit
A second power distribution unit can be installed to provide power to additional devices.
!
CAUTION:
Total power cannot exceed 275 Watts. The maximum ISDN terminal mixture is twenty
four 7500-series and twenty four 8500-series terminals.
The maximum DCP terminal mixture is twenty four 7400-series and twenty four
8400-series or sixty four 8400-series terminals.
The expanded power distribution unit kit contains:
• One 1146B2 Power Distribution Unit
• One “T” Cable
• Two #8-32 x 1/2-inch Shoulder Screws
• One #8-32 x 1 inch Screw
• One Spacer Bracket
Refer to ‘‘Expanded Power Distribution Unit’’ on page 150
while installing the power
distribution unit.
1 Set the spacer bracket onto the mounting plate and secure with the #8-32 x 1/2-inch
shoulder screws. The spacer bracket is not shown in the figure but is installed behind the
top power distribution unit.
2 Slide the keyhole slots in the power distribution unit over the shoulder screws.
3 Insert the #8-32 x 1 inch screw through the distribution unit, through the spacer bracket,
and into the plate. The mounting hole is located just above the wire clip. Tighten the
screw securely.
4 Set the battery back-up switch to the 1-32 (down) position.
5 Power-down the 1145B2 unit as described on the label on the side of the unit.
6 Remove the output power cable between the 1145B2 and the 1146B2 units. The cable
will not be reused.
Back-Up Battery Rating
Battery Rating
1148B 2.5 amp-hours
1149B 5 amp-hours
1147B 8 amp-hours